• Maher Cramer posted an update 1 year, 5 months ago

    Additionally, the attribution of far-field optical response to higher-order multipoles highlights the sensitivity offered by these orientation-dependent characterization techniques to probe the influence of localized electromagnetic field gradients on a plasmonic response. The sensitivity afforded by orientation-dependent optical characterization is further observed by the manifestation in both plasmon and chiral plasmon responses of unpredicted structural nanocrescent variance (e.g., left- and right-tip asymmetry) not physically resolved through topographical imaging.Graphene-based photodetectors have shown responsivities up to 108 A/W and photoconductive gains up to 108 electrons per photon. These photodetectors rely on a highly absorbing layer in close proximity to graphene, which induces a shift of the graphene chemical potential upon absorption, hence modifying its channel resistance. However, due to the semimetallic nature of graphene, the readout requires dark currents of hundreds of microamperes up to milliamperes, leading to high power consumption needed for the device operation. Here, we propose a different approach for highly responsive graphene-based photodetectors with orders of magnitude lower dark-current levels. A shift of the graphene chemical potential caused by light absorption in a layer of colloidal quantum dots induces a variation of the current flowing across a metal-insulator-graphene diode structure. Owing to the low density of states of graphene near the neutrality point, the light-induced shift in chemical potential can be relatively large, dramatically changing the amount of current flowing across the insulating barrier and giving rise to an alternative gain mechanism. This readout requires dark currents of hundreds of nanoamperes up to a few microamperes, orders of magnitude lower than that of other graphene-based photodetectors, while keeping responsivities of ∼70 A/W in the infrared, almost 2 orders of magnitude higher than that of established germanium on silicon and indium gallium arsenide infrared photodetectors. This makes the device appealing for applications where high responsivity and low power consumption are required.We report compact, scalable, high-performance, waveguide integrated graphene-based photodetectors (GPDs) for telecom and datacom applications, not affected by dark current. Selleck AdipoRon To exploit the photothermoelectric (PTE) effect, our devices rely on a graphene/polymer/graphene stack with static top split gates. The polymeric dielectric, poly(vinyl alcohol) (PVA), allows us to preserve graphene quality and to generate a controllable p-n junction. Both graphene layers are fabricated using aligned single-crystal graphene arrays grown by chemical vapor deposition. The use of PVA yields a low charge inhomogeneity ∼8 × 1010 cm-2 at the charge neutrality point, and a large Seebeck coefficient ∼140 μV K-1, enhancing the PTE effect. Our devices are the fastest GPDs operating with zero dark current, showing a flat frequency response up to 67 GHz without roll-off. This performance is achieved on a passive, low-cost, photonic platform, and does not rely on nanoscale plasmonic structures. This, combined with scalability and ease of integration, makes our GPDs a promising building block for next-generation optical communication devices.More efficient thermoelectric devices would revolutionize refrigeration and energy production, and low-dimensional thermoelectric materials are predicted to be more efficient than their bulk counterparts. But nanoscale thermoelectric devices generate thermal gradients on length scales that are too small to resolve with traditional thermometry methods. Here we fabricate, using single-crystal bismuth telluride (Bi2Te3) and antimony/bismuth telluride (Sb2-xBi x Te3) flakes exfoliated from commercially available bulk materials, functional thermoelectric coolers (TECs) that are only 100 nm thick. These devices are the smallest TECs ever demonstrated by a factor of 104. After depositing indium nanoparticles to serve as nanothermometers, we measure the heating and cooling produced by the devices with plasmon energy expansion thermometry (PEET), a high-spatial-resolution, transmission electron microscopy (TEM)-based thermometry technique, demonstrating a ΔT = -21 ± 4 K from room temperature. We also establish proof-of-concept for condensation thermometry, a quantitative temperature-change mapping technique with a spatial precision of ≲300 nm.Miniaturized total analysis systems, for the rapid detection of disease biomarkers, with features including high biomarker sensitivity, selectivity, biocompatibility, and disposability, all at low cost are of profound importance in the healthcare sector. Within this frame of reference, we developed a lab-on-a-carbohydrate-microneedle biodevice by integrating localized surface plasmon resonance (LSPR) paper-based substrates with biocompatible microneedles of high aspect ratio (>601 lengthwidth). These microneedles are completely fabricated with carbohydrate (maltose) and further coated with poly lactic-co-glycolic acid (PLGA), which together serves the purpose of fluid channels. The porous nature of PLGA, in addition to drawing blood by capillary action, filters out the whole blood, allowing only the blood plasma to reach the biorecognition layer of the developed biodevice. While the use of maltose provides biocompatibility to the microneedle, the axial compression and transverse load analysis revealed desired mechanical strength of the microneedle, with mechanical failure occurring at 11N and 9 N respectively for the compressive and transverse load. For a proof-of-principle demonstration, the developed biodevice is validated for its operational features by direct detection of cystatin C in finger-prick blood and up to a concentration of 0.01 μg/mL in buffered conditions using the LSPR technique. Furthermore, by changing the biorecognition layer, the use of the developed needle can be extended to other disease biomarkers, and therefore the innovation presented in this work represents a hallmark in the state of the art of lab-on-a-chip biodevices.

Demos
Buy This Template
Recash test site
Logo
Register New Account